YLG-0.30 Marine Hydrophore Tank

1.Technical Requirements:
1). Flange Standard:CB/T46-1999 PN1.0;
2). The shell cover thickness including the forming thinning;
3). The system including security settings;
4). Pipes and support same as the drawings.
2. Outer Joint:
Mark | Name | Size | Standard |
a | relief outlet | 3/4' | |
b | Water Inlet | DN32 | CB/T46-1999 PN1.0 |
c | Compressor Air Inlet | 3/8' | CB*53-80 |
d | Water Outlet | DN32 | CB/T46-1999 PN1.0 |
3. Design Datas:
Working Pressure | 0.6Mpa |
Design Pressure | 0.7Mpa |
Working Temp. | 0~45℃ |
Design Temp. | 50℃ |
Main Materials | CCS-B/SS304/SS316 |
corrosion allowance | 0.75mm |
welded joint coefficient | 0.6 |
Capacity | 0.3m³ |
The relief valve pressure jump | 0.63MPa |
G.W. | 265 Kgs (with standard export wooden case) |
N.W. | 215 Kgs |
Tel:+ +8613588244516
Email: