Marine Explosion-proof Manual Fire Call Point _MARINE FIRE ALARM SYSTEM_MARINE FIRE FIGHTING EQUIPMENT_PRODUCTS_TAIHANG

MARINE FIRE ALARM SYSTEM

Marine Explosion-proof Manual Fire Call Point



3572ffd402da8e0.png

What Is It?

Marine explosion-proof manual fire call point is designed according to EN6009-0, En6009-1 and EN54 standard. Enclouse material is UV and corrosion resistance GRP.This product is certified for use and installation in Zone1 and Zone 2 areas with gases groups of IIA, IIB plus H2 and temperature classification of T6.It specially applies to Oil & Gas,Offshore Platform, Chemical, Petrochemical, Petrochemical, Refinery and Marine Industries etc.

Working Principle

The manual call point is very conenient to use. No hammer is required. The design of two LED indicators (Green and Red) is unqiue. During normal operation, the Green LED is on.When device fault or alarm status arises, the Green LED will be cut off and The Red one will be on.

Specification

Operating Temperature Range:-40℃~70℃

Operating Humidity Range: be small or equal to 95% Noncondensing

Operating Voltage:Loop24V

Standby Current:0.8mA

Alarm Current:2mA

Dimensions:196mm* 129mm * 95mm

Some of above those parameter can be customized accoring to your personal requirement!

Features

I. Crrrosion resistant

II.Suitable for explosion protected applications

III.Internal or exposed external application

IV.Stainless steel lift flap

V.Double pole switch

VI.LED activation indication